Take off the fuel pump relay [А].
Set the hand tester to the x 1 kΩ range and make the measurements shown in the table.
Special Tool - Hand Tester: 57001-1394
★ If the tester readings are not as specified, replace the fuel pump relay.
★ If the tester readings are normal, check the fuel pump operation.
Caution!
- Use only Hand Tester 57001-1394 for this test. An ohmmeter other than the Kawasaki Hand Tester may show different readings.
- If a megger or a meter with a large-capacity battery is used, the pump relay will be damaged.
Fuel pump relay internal resistance
Range x 1 kΩ | Tester (+) Lead Connection | ||||
1 | 2 | 3 | 4 | ||
* (-) | 1 | — | ∞ | ∞ | ∞ |
2 | ∞ | — | ∞ | ∞ | |
3 | ∞ | 10-100 | — | ∞ | |
4 | ∞ | 20-200 | 1-5 | — |
(-)* : Tester (-) Lead Connection.