- ABS motor relay for continuity
Connect the pocket tester (Ωx1) to the terminals of ABS motor relay.
Check for continuity between terminals «1» and «2» of the ABS motor relay.
ABS motor relay resistance: 50-150Ω.
Pocket tester: 90890-03112.
Analog Pocket tester: YU-03112-C.
Tester positive probe → Terminal «2»
Tester negative probe → Terminal «1
Tester reading is «∞». → Replace the ABS motor relay.
Caution! Do not reverse the connections. If the pocket tester leads are connected in reverse to terminals «1» and «2», a correct pocket tester reading cannot be obtained.
Connect the positive battery terminal to terminal «2» and the negative battery terminal to terminal «1», and then check for continuity between terminals «3» and «4» of the ABS motor relay.
Tester positive probe → Terminal «3»
Tester negative probe → Terminal «4»
Tester reading is «∞». → Replace the ABS motor relay.
Cautions!
- Be sure to connect the pocket tester positive and negative probes correctly. If the pocket tester probes are connected in reverse, the diode of the ABS motor relay will be broken.
- When connecting the ABS motor relay and battery terminals, be careful not to short-circuit the positive and negative battery terminals.