Remove fasteners securing exhaust manifold.
Remove exhaust manifold.
Installation is the reverse of the removal procedure.
Caution!
- After a trial run, read out Motronic fault memory.
- Note position of wiring for oxygen sensor.
Tightening torque:
- Clamp, manifold to front silencer (apply Never Seeze to clamp seat) — 45 Nm
- Exhaust manifold to cylinder head — 21 Nm