Caution! Never insert the tester probes into the coupler terminal slots (1). Always insert the probes from the opposite end of the coupler, taking care not to loosen or damage the leads.
- Pocket tester: 90890-03112
Note:
- Before checking for continuity, set the pocket tester to "0" and to the "Ω x 1" range.
- When checking for continuity, switch back and forth between the switch positions a few times.
The terminal connections for switches (e.g., main switch, engine stop switch) are shown in an illustration similar to the one on the left.
The switch positions (a) are shown in the far left column and the switch lead colors (b) are shown in the top row in the switch illustration.
Note: "O—O" indicates a continuity of electricity between switch terminals (i.e., a closed circuit at the respective switch position).
The example illustration on the left shows that:
There is continuity between blue/red and red when the switch is set to "".
There is continuity between blue/red and blue, between brown/blue and red, and between blue/yellow and black when the switch is set to "ON".