![](https://motoinstruction.ru/img/honda/9/116608.jpg)
Check the needle bearing for abnormal wear or damage.
Check the starter driven gear for abnormal wear or damage.
Measure the starter driven gear O.D.
Service limit: 57.639 mm (2.2692 in).
Measure the starter driven gear I.D.
Service limit: 44.10 mm (1.736 in).
![](https://motoinstruction.ru/img/honda/9/116609.jpg)