Disconnect and connect
Disconnect
1. See Figure A-34. Remove wire clip (1).
2. Pull the connector from the sensor.
Connect
1. Align the connector housings.
2. Press the housings together.
3. Install wire locking clip.
Remove terminal
PART NUMBER | TOOL NAME |
GA500A | SNAP-ON TERMINAL PICK |
1. See Figure A-34. Remove sealing boot (2) from housing (5).
2. Insert the smallest pins of the SNAP-ON TERMINAL PICK (Part No. GA500A) into the cavities (3) on each side of the terminal to compress the tangs (6) on each side of the terminal (4).
3. Gently pull on the wire to remove the terminal.
Install terminal
1. See Figure A-34. Bend the tangs (6) on each side of the terminal outward.
2. Align terminal (4) to the housing (5). Install the terminal into housing. Terminal will snap into place.
Figure A-34. Tyco Sealed Timer Connector: 1. Wire clip; 2. Sealing boot; 3. Cavity (2); 4. Terminal; 5. Housing; 6. Tang