Removal
Remove the clamp bolts and clamp.
![](https://motoinstruction.ru/img/honda/9/116531.jpg)
Remove the stator bolts and wire grommets, then remove the stator and ignition pulse generator from the left crankcase cover.
Installation
Clean the mating surfaces of the left crankcase cover and left crankcase.
Install the stator onto the left crankcase cover.
Apply liquid sealant to the wire grommets seating surface and install the grommets into the grooves in the left crankcase cover.
Route the wires properly and install the clamp with the bolts.
Apply locking agent to the stator bolt threads, and install and tighten them.
Apply locking agent to the ignition pulse generator bolt threads, and install and tighten them.
![](https://motoinstruction.ru/img/honda/9/116532.jpg)
Apply locking agent to the bolt threads
Install the clamp and tighten the clamp bolt securely.