Turn the ignition switch to "ON" and measure the voltage between the following terminals of the bank angle sensor 3P green connector with the connector connected.
TERMINAL | STANDARD |
White/black (+) - Green (-) | Battery voltage |
Red/white (+) - Green (-) | 0 - 1 V |
Turn the ignition switch to "OFF".
Disconnect the bank angle sensor 3P green connector.
Remove the battery case (page 16-7).
Remove the screws and bank angle sensor.
Do not disconnect the bank angle sensor connector during inspection.
Place the bank angle sensor horizontal as shown, and turn the ignition switch to "ON".
The bank angle sensor is normal if the engine stop relay clicks and power supply is closed.
Incline the bank angle sensor approximately 42.5 degrees to the left or right with the ignition switch turned to "ON".
The bank angle sensor is normal if the engine stop relay clicks and power supply is open.
If you repeat this test, first turn the ignition switch to "OFF", then to "ON".
Removal/installation
Disconnect the bank angle sensor 3P green connector.
Remove the battery case (page 16-7).
Remove the screws and bank angle sensor.
Installation is in the reverse order of removal.
install the bank angle sensor with its "UP" mark facing up and towards the battery case.